Posted in

How to prevent leaks with solar mounting accessories?

Hey there, fellow solar pros, installers, and project managers — let’s talk about something that’s been tripping up even the most experienced solar teams lately: leaks. You’d think with all the fancy tech going into solar panels, a simple leak could derail an entire install’s performance, and bad news travels fast. As a solar mounting accessories supplier, I’ve seen way too many jobs go south because of a tiny, overlooked part. So today, I’m breaking down how to actually stop leaks before they start — no jargon, no fluff, just stuff that works because we’ve tested it ourselves. Solar Mounting Accessories

First, let’s cut to the chase: most leaks aren’t from bad panels or even faulty roof work. They’re from the mounting hardware we use to hold everything in place. Think about it: every time you drill a hole into a roof, that’s a potential entry point for water. If you don’t seal that right, even a light rain can seep under your panels, rot roof decking, corrode wiring, and turn a $10k solar install into a $5k headache. I’ve had installers reach out to me saying their last job had a leak 6 months post-install, and 9 times out of 10, it traced back to something simple — like using the wrong flashing or skipping a gasket.

Let’s start with the basics: your mounting accessories’ foundation — the flashing. Not all flashing is created equal. We see a lot of guys going cheap on aluminum flashing, but aluminum can corrode over time when paired with metal roofs, especially in coastal areas with salt air. Our go-to here is EPDM flashing? No, wait, let’s be real — no one wants another acronym to remember. It’s that soft, rubbery flashing that’s flexible, sticks to almost anything (asphalt shingles, metal, tile), and stands up to UV rays way better than plastic. Wait, no, let’s clarify: we stock two types of flashing for different roofs. For asphalt shingles, we use self-sealing butyl rubber flashings — the kind that has a sticky backing you press down firmly on. For metal roofs, we use aluminum flashings with a neoprene gasket between the mounting bracket and the metal panel. That gap is key, right? Metal expands and contracts with temperature changes, so a rigid flashing will crack and let water in. A flexible gasket absorbs that movement.

Next up: gaskets and washers. These little guys are unsung heroes. A lot of installers skip the secondary gasket on the bolt itself, just using one under the bracket. But here’s the thing: when you tighten a bolt into a mounting leg, the metal presses on the roof’s underlayment. Even if you have a flashing, if the bolt hole isn’t sealed around the shank, water can creep up the side of the bolt. We sell dual EPDM gaskets for this exact reason — one under the bracket to seal the hole, and another between the bolt head and the bracket to create a double barrier. Also, don’t forget the washer! A flat rubber washer between the bolt head and bracket prevents the bolt from digging into the mounting hardware and tearing the gasket. I’ve seen installers tighten bolts too hard, the washer slices through the gasket, and boom — leak within a month. Pro tip: use a torque wrench, not a impact gun, for mounting hardware. Impact guns over-tighten everything, which compromises gaskets and can crack flashing.

Wait, let’s talk about roof compatibility. That’s where a lot of mistakes happen. For tile roofs, like clay or concrete, you can’t just drill a hole and slide a flashing on top — the tile is curved, so you need a tile mounting bracket with a custom base that fits under the tile’s lip. We make tile mounts with pre-sealed bases so you don’t have to mess with cutting your own seal. If you cut your own seal for tile roofs, you’re asking for gaps. And for flat roofs? Oh man, flat roofs have their own set of issues. They drain slow, so water can pool around mounting bases if you don’t have a raised flange. Our flat roof mounting kits come with 2-inch high flanges that lift the base off the roof membrane, so water runs past instead of pooling. We’ve even had a test job in Florida where a flat roof mount without the flange had a leak after a heavy rain, and the one with the flange was bone dry. Don’t skip that flange — it’s not a “nice-to-have,” it’s a leak preventer.

Another big one: compatibility between metal materials. This is something most installers don’t think about, but it’s a silent killer. If you mount a steel bracket to an aluminum roof, they’ll galvanically corrode each other. That corrosion creates tiny gaps where water gets in, and over time, the bracket can even loosen. We stock bimetallic washers for this — they act as a barrier between steel and aluminum, stopping the corrosion. I remember a contractor told me he didn’t use the washers on a 20-job project, and 3 of them had corrosion-related leaks within a year. Total fix: we sent over the bimetallic washers, and haven’t had a single complaint since. It’s a $0.05 part that saves thousands — why would you skip that?

Let’s move to installation mistakes that even good installers make. First, don’t over-flash. Wait, what? You know how some guys slap extra sealant around the flashing? Too much sealant can crack as it cures, or it can block roof drainage points. A proper flashing should lie flat against the roof, no wrinkles, and be sealed with a thin, even layer of butyl tape. Wrinkles mean air pockets, which mean water can get under. We always tell our customers to test flashings by pouring a cup of water over them after installation — if it runs straight off, you’re good. If it pools in a wrinkle, fix the wrinkles before moving on. That 2-minute test saves you hours of callbacks later.

Second, check your underlayment. A lot of installers treat mounting hardware like it’s separate from the roof’s underlayment, but it’s not. The flashing should sit on top of the underlayment, not through it. Wait, no — when you drill the hole, the underlayment gets cut, so the flashing has to cover that cut. We make flashings that are 4 inches wider on all sides than the mounting base, so they fully cover the drilled hole and overlap the underlayment by at least an inch. That way, even if water seeps under the shingles, it hits the flashing, not the cut in the underlayment. Also, if your roof has ice and water shield (the sticky stuff for cold climates), make sure the flashing overlaps that shield by 2 inches. Ice and water shield is way more waterproof than regular underlayment, so that extra overlap is a game-changer in places like Minnesota or Canada.

What about existing roofs? Like, if you’re retrofitting a solar system on an old roof, not a new build. That’s where leaks are way more common. Old roofs have worn underlayment, cracked shingles, maybe even soft spots. Our advice here: if a roof is more than 15 years old, do a moisture test before installing. We can even send a rep to help, but if you’re doing it yourself, use a moisture meter — if the reading is over 15%, the roof is too soft, and you should replace it before mounting. Also, for retrofits, we sell flexible silicone sealant that’s compatible with old roof materials, but only as a secondary seal. Never use silicone as your only seal — it can peel off over time, especially in hot areas. Stick to butyl for the main seal, and silicone only to fill tiny gaps between flashing and shingles that are too small for the flashing itself.

Wait, let’s talk about maintenance, because preventing leaks isn’t just installation — it’s upkeep. We tell all our customers to do a 6-month check: look for cracked gaskets, loose bolts, peeling flashing. Wind and temperature changes can loosen things over time. I once had a installer come to me because a job he did 2 years prior had a leak, and when we checked, a gasket had shrank from UV exposure. Turns out, he didn’t use UV-resistant gaskets. Now, all our gaskets are rated for 25+ years of UV exposure, so that’s not an issue anymore. Pro tip: when ordering gaskets, specify UV-resistant if the job is in a sunny climate — Arizona, Texas, Florida. It costs a little more, but you won’t be replacing them every 5 years.

Let’s wrap this up with a real example. Last year, a contractor in Texas hit me up panicking because his 10-install project had 2 leaks within 3 months. He had used cheap flashing and skipped the bimetallic washers for metal roofs. We sent over our UV-resistant butyl flashings, bimetallic washers, and dual gaskets, and helped him re-seal the problem areas. Now, 18 months later, he’s told me not a single one of those jobs has had a leak. That’s the difference between using the right mounting accessories and cutting corners.

Here’s the thing: solar mounting accessories aren’t just for holding panels up. They’re the first line of defense against leaks. Every part — from the flange under the base to the gasket on the bolt — works together to keep water out. You don’t need fancy, expensive parts, but you do need parts that are matched to your roof, installed correctly, and compatible with each other. No more guessing. No more callbacks. Just solid, leak-free installs.

If you’re dealing with a leak problem on a current project, or you want to make sure your next install doesn’t end up with a water issue, hit us up. We can help you pick the right flashings, gaskets, and brackets for your specific roof type, no sales pitch — just straight advice from a supplier that’s been in the game long enough to know what works. Don’t let a leak ruin your reputation or your profit. Let’s get it right the first time.

Bespoke Aluminium Extrusions References

  1. International Code Council. (2021). International Residential Code for One- and Two-Family Dwellings: Roof Penetration Sealing Requirements.
  2. Solar Energy Industries Association. (2022). Best Practices for Solar Mounting System Installation: Water Intrusion Prevention.
  3. American Society of Testing and Materials. (2020). Standard Test Methods for Rubber Gaskets for UV Resistance and Water Tightness.
  4. National Roofing Contractors Association. (2021). Roof Flashing and Penetration Sealant Materials Compatibility Guide.